• Users Online: 367
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 6  |  Issue : 3  |  Page : 69-73

Evaluation of efficacy of various fixation devices in management of anterior mandibular fractures: A prospective clinical study


Department of Oral and Maxillofacial Surgery, Sri Sai College of Dental Surgery, Hyderabad, Telangana, India

Correspondence Address:
Dr. Uday Kiran Uppada
Department of Oral and Maxillofacial Surgery, Sri Sai College of Dental Surgery, Vikarabad, Hyderabad, Telangana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jdrr.jdrr_20_19

Rights and Permissions

Aim: The aim of this study was to evaluate the efficacy and reliability of fracture management in the anterior mandible using miniplates (MPs), lag screws (LSs), three-dimensional (3D) plates, and Herbert screws. Materials and Methods: The study consists of forty patients randomly divided into four groups of ten, undergoing open reduction internal fixation of anterior mandible fractures using MPs, LSs, 3D plates, or Herbert screw. All the patients were evaluated for stability of fracture fragments, duration of procedure, requirement of maxillomandibular fixation, and other associated complications. Results: The results of this study showed that each fixation device has its own merits and demerits. The rectangular plates achieved good stability, but its placement and adaptation was challenging in certain clinical scenarios when the anterior mandibular height was less, especially in females and in situations where the fracture line was in close proximity to the mental foramen. The placement of LS and Herbert screw was technique sensitive but did achieve good initial stability in addition to shortening the procedure time. The MPs were more versatile but required more operating time and hardware for the management of the anterior mandibular fractures. Conclusion: All of these modalities were able to achieve satisfactory final outcome. The rigid fixation techniques achieved similar results with less hardware and required lesser times. The MP fixation techniques, on the other hand, are more versatile and less technique sensitive.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed171    
    Printed24    
    Emailed0    
    PDF Downloaded55    
    Comments [Add]    

Recommend this journal